CONTROLLERModify Date : 2020-07-28 10:42:13
Power Supply Voltage : AC100V ~ AC240V
Sensor Voltage : DC24V / 0V (Ground), 200mmA
Improved Products from Model SWH-5B
Additional improved function
1. Added S2 Mode Counter function (2-step speed and Complete stop)
2. Installed Output Line earth leakage sensing circuit
3. Installed Output Noise Filter
4. Added Automatic Compensator Function of Input variation voltage, Output voltage (ON / OFF possible)
5. Added Output waveform selection function
Full-Wave : DF-5A output pulse shape
Half-wave : Resonance phenomenon improve waveform, Sharply reduced noise,
Show half-wave with or without dot ( . ) beside V mark
6. Distinguishes between Parameter user mode and Engineer mode
7. Change channel operation method (Can save and operate with 4-channels Individual main channel)
Power Supply Voltage : AC100V ~ AC240V
Sensor Voltage : DC24V / 0V (Ground), 200mmA
Improved Products from Model SWH-5B
Additional improved function
1. Added S2 Mode Counter function (2-step speed and Complete stop)
2. Installed Output Line earth leakage sensing circuit
3. Installed Output Noise Filter
4. Added Automatic Compensator Function of Input variation voltage, Output voltage (ON / OFF possible)
5. Added Output waveform selection function
Full-Wave : DF-5A output pulse shape
Half-wave : Resonance phenomenon improve waveform, Sharply reduced noise,
Show half-wave with or without dot ( . ) beside V mark
6. Distinguishes between Parameter user mode and Engineer mode
7. Change channel operation method (Can save and operate with 4-channels Individual main channel)
UL인증 주파수 컨트롤러 입니다.
UL-certification Frequency Controller DF-5C
Frequency Controller Key Features | ||
* Size : 56(82)mmW * 145mmL * 145mmH (160mm Including VR) | ||
* Using OLED window display to see Operation and Setting status. | ||
* Time setting and Multi-function by 2 numbers sensors (AND, OR, SET, 2step speed) | ||
* External volume installation and Output controllability by DC 0 ~ 5V. | ||
* Solenoid valve and indicator lamp drive from outside by installed relay contact. | ||
* Using Separation type for Control signal (ON / OFF control by PLC and External signal) | ||
* Bowl / Hoper Interlock control (Stopping the Hopper Feeder when the Bowl Feeder is stopped) | ||
|
Frequency Controller Key Features | ||
* Size : 56(82)mmW * 145mmL * 145mmH (160mm Including VR) | ||
* Using OLED window display to see Operation and Setting status. | ||
* Time setting and Multi-function by 2 numbers sensors (AND, OR, SET, 2step speed) | ||
* External volume installation and Output controllability by DC 0 ~ 5V. | ||
* Solenoid valve and indicator lamp drive from outside by installed relay contact. | ||
* Using Separation type for Control signal (ON / OFF control by PLC and External signal) | ||
* Bowl / Hoper Interlock control (Stopping the Hopper Feeder when the Bowl Feeder is stopped) | ||
|
Frequency Controller Key Features | ||
* Size : 56(82)mmW * 145mmL * 145mmH (160mm Including VR) | ||
* Using OLED window display to see Operation and Setting status. | ||
* Time setting and Multi-function by 2 numbers sensors (AND, OR, SET, 2step speed) | ||
* External volume installation and Output controllability by DC 0 ~ 5V. | ||
* Solenoid valve and indicator lamp drive from outside by installed relay contact. | ||
* Using Separation type for Control signal (ON / OFF control by PLC and External signal) | ||
* Bowl / Hoper Interlock control (Stopping the Hopper Feeder when the Bowl Feeder is stopped) | ||
|
*.size: 42 * 145 * Height 105 (including VR)
*.Analog Circuit
*.main inputpower on/off control
*.Electrical/Half-wave Switch
*.SOFT 0.1/0.5 Selectable
*.Set limit range with secondary volume